
Add to Cart
Top Heat Efficiency Non Pollution Fully Automatic Electric Heating Hot Water Boiler For Troop
Hot water boiler maintenance measures
A hot water boiler is a heat conversion device that provides hot water, which transmits the heat released by the burning fuel to the water in the pot, raising the temperature of the water in the pot for heating or living. Hot water boiler sin and export flow is water, most of it is through the pressure of the pump forced circulation, but also some in the boiler body by different water temperature caused by the severe difference in natural circulation. Intermediate placement, it needs to be mentioned: the opener is only used in the normal pressure boiler system equipment, in fact, is a valve, we often call it the system open-closed valve. Mainly in order to prevent the system water reflux into the boiler, because the boiler is generally designed to have an open water tank or often through the atmosphere of the discharge pipe, if the water from the system back to fill the boiler, the system water will all overflow from the boiler, can be flooded boiler room. The earliest before there was no opening and closing valve design, the regular pressure boiler a stop furnace, the furnace personnel have to immediately close the return valve, to ensure that the water does not reverse. The open-closed valve solves the problem.
Part of product parameters
CWDR0.7-95/70
NO; | Name | Unit | Number | Description |
1 | Rated efficiency | MW | 0.7 | |
2 | Water volume | M³ | 1.4 | |
3 | Rated outlet/inlet water temperature | ℃ | 95/70 | |
4 | Heating efficiency | % | 99 | |
5 | Output/inlet diameter | mm | DN100 | |
6 | Design fuels | / | Electric | |
7 | Blow down valve diameter | mm | DN100 | |
8 | Heating area(room) | ㎡ | 6000 | |
9 | Hot water output | M³/h | 18 | |
10 | Bulk size | mm | 2400×1200×1800 |
CWDR1.4-95/70
NO; | Name | Unit | Number | Description |
1 | Rated efficiency | MW | 1.4 | |
2 | Water volume | M³ | 3.75 | |
3 | Rated outlet/inlet water temperature | ℃ | 95/70 | |
4 | Heating efficiency | % | 99 | |
5 | Output/inlet diameter | mm | DN125 | |
6 | Design fuels | / | Electric | |
7 | Blow down valve diameter | mm | DN125 | |
8 | Heating area(room) | ㎡ | 12500 | |
9 | Hot water output | M³/h | 36 | |
10 | Bulk size | mm | 2800×1700×2300 |
Pre-sale service:
We help customer choose the best boiler model according to
different requirements of various industry. Before delivery we
will provide foundation drawing, layout drawing, boiler room
layout, etc.
In-sale service:
We keep 24 hours online and keep close contacts during the
production process to ensure on time delivery with perfect
finished product.
After-sale service:
1. provide full range of original spare parts.
2. Engineers abroad installation and commissioning service is
available.
3. Our engineers will held a training for boiler workers to
ensure the safe operation.
4. Free maintenance and repair for one year and lifelong
service.
Boiler application areas