Add to Cart
High Efficiency Electric Heating Thermal Oil Boiler For Shipping Industry
The structural principle of the thermal oil furnace is through the high temperature oil pump, the heating oil is transmitted to the
heat ingress, after heat unloading, degrees and then returned to the heat transfer oil heating tube, using the high temperature oil
pump will be heat ingressed to circulate the heat transfer, the heat energy is passed to the heat equipment, and then re-through
the circulation pump, return to the heater, absorb heat, and then pass to the heat equipment, so repeated cycle to achieve
continuous transfer of heat.
Part of product parameters
YY(Q)W-700Y(Q)
NO; | Name | Unit | Number | Description |
1 | Rated thermal power | KW | 700 | |
2 | Rated working power | Mpa | 1.0 | |
3 | Rated inlet/outlet ℃ | ℃ | 310/290 | |
4 | Design efficiency | % | 92.45(Oil) 92.13(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | Be added economizer |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 70.77(Oil) | |
Nm³/h | 86.53(Gas) | Be added economizer | ||
9 | Radiation heating area | m² | 7.199 | |
Convection heating area | m² | 28.71 | ||
GGH heating area | m² | 10.965 | ||
10 | Fume temperature | ℃ | 136.68(Oil) | |
℃ | 137.02 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | Be added economizer |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 0.46 | |
14 | Bulk weight | kg | 4250 | |
15 | Bulk size | mm | 3256×1727×2181 | |
16 | Chimney | mm | Φ325×10000 | |
17 | Combustion model | / | Micro positive pressure | Chamber combustion |
18 | Boiler structure feature | Horizontal-type chamber combustion | ||
19 | Control way | Full automation/Manual | ||
20 | Ignition way | High-tension/Electrode |
YY(Q)W-1400Y(Q)
NO; | Name | Unit | Number | Description |
1 | Rated thermal power | KW | 1400 | |
2 | Rated working power | Mpa | 1.0 | |
3 | Rated inlet/outlet ℃ | ℃ | 310/290 | |
4 | Design efficiency | % | 92.33(Oil) 92.03(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | Be added economizer |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 138.93(Oil) | |
Nm³/h | 169.53(Gas) | Be added economizer | ||
9 | Radiation heating area | m² | 13.124 | |
Convection heating area | m² | 71.233 | ||
GGH heating area | m² | 29.845 | ||
10 | Fume temperature | ℃ | 139.26(Oil) | |
℃ | 139.27 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | Be added economizer |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 1.08 | |
14 | Bulk weight | kg | 8389 | |
15 | Bulk size | mm | 4869×2070×2698 | |
16 | Chimney | mm | Φ400×10000 | |
17 | Combustion model | / | Micro positive pressure | Chamber combustion |
18 | Boiler structure feature | Horizontal-type chamber combustion | ||
19 | Control way | Full automation/Manual | ||
20 | Ignition way | High-tension/Electrode |
Pre-sale service:
We help customer choose the best boiler model according to
different requirements of various industry. Before delivery we
will provide foundation drawing, layout drawing, boiler room
layout, etc.
In-sale service:
We keep 24 hours online and keep close contacts during the
production process to ensure on time delivery with perfect
finished product.
After-sale service:
1. provide full range of original spare parts.
2. Engineers abroad installation and commissioning service is
available.
3. Our engineers will held a training for boiler workers to
ensure the safe operation.
4. Free maintenance and repair for one year and lifelong
service.